| Product Name: |
Model LZ Rotor Meter |
|
|
 |
| Model: |
LZ |
|
| Products: |
Model LZ rotor flowmeter is suitable to measurement of volume flow rate of flowing liquid, gas or vapor in enclosed type piping. It has field mechanical director, 4~20mA output for choice. It is broadly applied to the control system in the fields of petroleum, chemical, medicine and metallurgical.
Feature
Good versatility: can measure liquid, gas and vapor.
Low flow rate: small flow quantity but better sensitivity.
Direct reading: big dial plate, clear reading.
Output 4-20mA(two wire system), suitable to control.
Specification
|
MODEL |
Upper Flow (m3/h) |
Span |
Error |
Pressure(MPa) |
|
20oC Water |
20oC Air |
LZZ-15 LZD-15 |
0.025 |
0.7 |
10 |
1.5 ~ 2.5 |
Normal less than 1.6mPa. More
than 1.6mPa must bulid. |
|
0.04 |
1.1 |
|
0.06 |
1.8 |
|
0.1 |
2.8 |
|
0.16 |
4 |
|
0.25 |
7 |
|
0.4 |
10 |
LZZ-25 LZD-25 |
0.6 |
16 |
| 1 |
30 |
| 1.6 |
45 |
| 2.5 |
70 |
LZZ-40 LZD-40 |
4 |
110 |
| 6 |
160 |
LZZ-50 LZD-50 |
10 |
250 |
|
16 |
400 |
LZZ-80 LZD-80 |
25 |
750 |
|
40 |
750 |
LZZ-100 LZD-100 |
60 |
1800 |
|
60 |
2500 |
LZZ-150 LZD-150 |
160 |
4000 |
Flow temperature: -80-120℃(>120℃ for special order)
Ambient temperature: -20-50℃
Relative humidity :≤80%
Working pressure: 1.6MPa(>1.6 for special order )
Output current: 4-20mA(two wire system)
Explode-proof: Ex ibⅡCT4
Pressure loss: 6.5kPa-38.2kPa
Supply voltage: 24VDC±4.8VDC
Transmission distance: 1km(cable with metallic shield). Conductor resistance is less than 100Ω
|
| Download: |
Flow meter Catalogue |
 |
| |
instruction Manual |
 |
|
|